Product Description
We wanted to bring the highest quality products available on the market with the newest technology and all for reasonable prices.... well we did just that with PeakHMI Contact us for a free demo download... sales@plccable.com
Downloadable software and the key will be emailed to you, this key will be installed on the local computer running the PEAK software application.
Supports just about all major brands of PLC's including Allen Bradley, Siemens, Omron, Automation Direct, Mitsubishi and more... Driver list on the bottom of the page
Peak HMI Features
- Unlimited tag count
- Analog
- Digital
- Host - Analog
- Host - Digital
- Host - Analog Pointer
- Host - Digital Pointer
- Unlimited external connections
- Unlimited graphic screens
- Unlimited HMI to HMI tag data connections
- HTTP Web serverExtensive help files
- 100% HTML
- Low bandwidth, unlimited clients, view/change any tag, view logs
- Camera snapshots
- Graphic screen snapshots
- OPC Data Access Server (DA 2.xx)
- OPC Data Access Client (Redundant -Hot Standby)
- DA 1.xx, DA 2.xx, DA 3.xx, DA XML 1.xx
- Item ID of server can be tagname
- Configured items can be published on server side
- Graphics editorUnlimited graphic screens
- Lines, Arc, Rectangle, Circles, Bitmaps, Polygons, etc.
- Grouping with editing/animations
- Grids
- Polygon editing
- Gradient fills
- Buttons, Gauges, Sliders, etc
- Commands Wizard
- Runtime screen printing
- Scripting engine (not required for graphic animation or user interaction)Trending
- Integrated Development Environment
- Runtime Editing
- Debugging
- Runtime scripts are compiled
- Script commands: AcknowledgeCommand, Add, AddDigital, AllTrue, AnyTrue, Average, CloseAlarmLogWindow, CloseAlarmWindow, CloseAllUserWindows, CloseEventWindow, ClosePortDiagnosticWindow, CloseTagMonitorWindow, CloseAWindow, ExecuteScript, GetSystemVariable, GetUserInputBoolean, GetUserInputBoolean4, GetUserInputDate, GetUserInputFloat, GetUserInputInteger, GlobalGet, GlobalSet, LaunchApplication, LogEvent, LogOff, LogOn, MousePosition, OpenAlarmLogWindow, OpenAlarmWindow, OpenAWindow, OpenAWindowEx, OpenDriveStatusWindow, OpenEventWindow, OpenPortDiagnosticWindow, OpenTagMonitorWindow, OpenWindowUserSelect, PlayBeep, PlaySound, PrintScreen, ReadValue, SetAlarmEnables, SetMAStationConfigurationName, SetPortReadEnable, SetWindowDate, SilenceAcknowledgeCommand, SilenceCommand, StartCameraRecording, StopCameraRecording, TimerGet, TimerSet, Valve2Input, WriteValue, WriteValuePulse
- Data logging
- AlarmingEvent logging
- Alarm logging
- Alarm grouping
- Runtime alarm enable/disable
- Email/SMS notification (optional acknowledgement)
- User Graphic Library
- Complex MA (Manual/Automatic) graphic object
- Video in user windows
- Frame capture
- Recording to AVI (10 fps)
- Video for Windows
- IP Camera
- Motion detection
- HMI to HMI video sharing
- Multiple language support (Configuration and runtime programs. Help files excluded.)Hard drive free space monitoring and alarming
- English
- Spanish
- PeakHMI MB RLL included
PeakHMI Drivers that are supported
- A/B DF1 (Redundant - Hot Standby)
- PLC5, SLC500, SLC 5/01 - 5/05, MicroLogix
- A/B Ethernet (Redundant - Hot Standby)
- ControlLogix, CompactLogix, FlexLogix
- RSLinx not required
- No third party driver required
- A/B Ethernet PCCC (Redundant - Hot Standby)
- SLC, MicroLogix, SLC 5/05, PLC5
- RSLinx not required
- No third party driver required
- Bacnet/IP (Redundant - Hot Standby)
- Analog Input, Analog Output, Analog Value, Binary Input, Binary Output,
- Binary Value, Loop, Multi State Input, Multi State Output, Averaging,
- Multi State Value, Life Safety Point, Life Safety Zone
- Read Property, Write Property
- Delta computer systems - motion controllers - Delta motion control protocol (DMCP)
- TCP/IP and UDP/IP
- Read and write all files and elements
- Collect plots using Method 2 - Advanced (No limit on plot size)
- DNP3 Master
- RS-232, RS-485 and TCP/IP
- DNP3 Outstation emulation
- TCP/IP
- Enron MODBUS
- RS-232 and TCP/IP
- All register types
- Fatek (Facon)
- RS-232/485, TCP/IP and UDP/IP
- GE SNP-X (Redundant - Hot Standby)
- All register types
- Long break or long break free
- GE SRTP (Redundant - Hot Standby)
- All register types
- IDEC (OpenNet) (Redundant - Hot Standby)
- All register types
- Keyence PLC (Redundant - Hot Standby)
- All register types
- K-Sequence (Redundant - Hot Standby)
- Automation Direct (DirectLogic, Koyo)
- All register types
- Master-K LS/LG Industrial Systems (Redundant - Hot Standby)
- Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS) (Redundant - Hot Standby)
- Mitsubishi FX 0,1,2,3 (Redundant - Hot Standby)
- All register types
- Bit, Word, Longword, Float
- Mitsubishi Serial (Redundant - Hot Standby)
- Protocol 3C, Format 1 or 4, Checksum or no checksum
- All register types
- Bit, Word, Longword, Float
- Mitsubishi TCP/IP (Redundant - Hot Standby)
- Protocol 3E
- All register types
- Bit, Word, Longword, Float
- MODBUS/J-Bus Serial (RS-232/485) ASCII
- Master
- Bit, Float, String, Word
- MODBUS/J-Bus Serial (RS-232) RTU (Redundant - Hot Standby)
- Master and Slave
- Bit, Float, String, Word
- MODBUS/J-Bus Serial (RS-485) RTU
- Master
- Bit, Float, String, Word
- MODBUS/J-Bus TCP/IP (Redundant - Hot Standby)
- Master and Slave
- Bit, Float, String, Word
- ODBC (Open Database Connectivity)
- All dynamic tag values output to unlimited number of concurrent databases
- Can be the source for analog or digital process variables from unlimited number of concurrent databases
- Omron FINS (RS-232) (Redundant - Hot Standby)
- C, CV or CS/CJ mode
- All register types
- Bit, Word, Longword, Float
- Omron FINS (TCP and UDP) (Redundant - Hot Standby)
- C, CV or CS/CJ mode
- All register types
- Bit, Word, Longword, Float, String
- Omron Hostlink/SYSMAC-WAY (Redundant - Hot Standby)
- All register types
- Bit, Word, Longword, Float
- Omni flow computers (Enron MODBUS) RS-232 and TCP
- All register types
- All report types
- Saia-Burgess
- Serial-S-Bus (RS232/485)
- Ether-S-Bus
- Registers, Counters, Timers, Flags, Inputs, Outputs, Data blocks
- All data types - bit, integer, float, string
- Siemens S7-200 (PPI) (Redundant - Hot Standby)
- Inputs, Outputs, Analog Inputs, Analog Outputs, Variable memory, Timers, Counters, Special memory
- All data types - bit, byte, word, double word, float, timer, counter, string
- Siemens S7-300/400 (MPI) (Redundant - Hot Standby)
- Inputs, Outputs, Internal memory, Timers, Counters
- All data types - bit, byte, word, double word, float, timer, counter
- Siemens S7-300/400/1200 (TCP) (Redundant - Hot Standby)
- Inputs, Outputs, Internal memory, Timers, Counters, Data blocks
- All data types - bit, byte, word, double word, float, timer, counter
- SNMP (Simple Network Management Protocol) Version 1
- UDP
- Traps with logging
- GetRequest/SetRequest
- Toshiba ASCII computer link protocol (RS-232/485)
- X, Y, R, S, T, C, D, L registers
- Bit, Word, Longword, Float, String
- Toshiba ASCII computer link protocol (UDP/IP)
- X, Y, R, S, T, C, D, L registers
- Bit, Word, Longword, Float, String